EN 1990:2002 Table A1.2(B) — STR/GEO persistent and transient design situations. National Annex may modify these values.
Site-independent wind constants and partial factors. Terrain roughness (z₀, zmin) and cpe,10 tables are fixed to EN 1991-1-4 Tables 4.1 and 7.1.
Material partial factors and steel constants used in Annex E calculations. Core material properties (fcv, Gc) are declared per panel variant in the Panel Library.
Characteristic screw resistances (NRk, VRk) are stored per screw type. The partial factor below is applied to obtain design values NRd = NRk / γM,f.
These are the coefficient presets applied when you choose a country on the calculator start screen. The active preset shown here is read from local storage.
| Category | Description | z₀ (m) | zmin (m) |
|---|---|---|---|
| 0 | Sea or coastal area | 0.003 | 1 |
| I | Open country, few obstacles | 0.01 | 1 |
| II | Agricultural land, low vegetation | 0.05 | 2 |
| III | Suburban / industrial / forest | 0.30 | 5 |
| IV | Urban area, > 15 m buildings | 1.00 | 10 |
| Zone | h/d ≤ 0.25 | h/d = 1 | h/d ≥ 5 |
|---|---|---|---|
| A (corner suction) | −1.2 | −1.2 | −1.2 |
| B (side suction) | −0.8 | −0.8 | −0.8 |
| C (far-side suction) | −0.5 | −0.5 | −0.5 |
| D (windward pressure) | +0.7 | +0.8 | +0.8 |
| E (leeward suction) | −0.3 | −0.5 | −0.7 |
Intermediate h/d values interpolated logarithmically per EN 1991-1-4 note.
| Zone | Suction cpe | Pressure cpe |
|---|---|---|
| F (corner) | −1.8 | 0 |
| G (edge strip) | −1.2 | 0 |
| H (interior edge) | −0.7 | 0 |
| I (interior) | −0.2 | +0.2 |
| Spans | α (shear at support) | Span M factor | Support M factor |
|---|---|---|---|
| 1 | 0 | 1 | 0 |
| 2 | 1 / (4(1+k)) | (1−α)² | 1 / (1+k) |
| 3+ | 1 / (5+2k) | (1−α)² | 8 / (10+4k) |
k = 3Bs / (L²·S) — shear flexibility parameter. k→0 approaches rigid-core beam theory.
| Roof pitch α | μ₁ |
|---|---|
| 0° – 30° | 0.8 |
| 30° – 60° | 0.8 × (60 – α) / 30 (linear) |
| ≥ 60° | 0 |